| DS-5424A | DS-5422A | DS-5414A | DS-5412A |
| Frequency bandwidth (-3dB) | 200MHz | 100MHz |
| Rise time | 1.75ns | 3.5ns |
| (Representative values) |
| Number of input channels | 4 | 2 | 4 | 2 |
| Maximum sampling speed | 2GS/s (when channels are coupled), 1GS/s (when all channels are used) |
| Equivalent sampling speed | 100GS/s |
| Peak detection resolution | 1ns |
| Averaging function | 2 to 256 times (power of 2 steps) |
| Memory length | 500k point/ch (all channels) |
| Vertical resolution | 8-bit |
| Input voltage range | 2mV/div ~ 10V/div |
| Offset voltage | 2mV/div ~ 50mV/div : ±1V, 50.2mV/div ~ 500mV/div : ±10V, 502mV/div ~ 10V/div : ±100V |
| Deskew | 0~500 ns |
| DC gain accuracy | ±(1.5% +0.5% full-scale) |
| Maximum input voltage | ±400 Vpk |
| Bandwidth limit filter | Analog type:20MHz,2MHz, 200kHz |
| Input coupling | GND, DC 1MΩ, AC1MΩ |
| Input impedance | 1 MΩ±1.0 % || 20 pF±2 pF(DC1MΩ) |
| Probe sense | Auto search:1:1, 10:1, 100:1, 1000:1 |
| Manual setting:1:1, 5:1, 10:1, 20:1, 50:1, 100:1, 200:1, 500:1, 1000:1, 2000:1 |
| Time axis range | 2ns/div ~ 50s/div | 5ns/div ~ 50s/div |
| Standard probe | SS-0130R (with standard number of channels) |
| Roll mode | 50ms/div ~ 50s/div (100kS/s max) |
| Clock accuracy | ±10 ppm |
| Trigger function |
| Trigger function | Edge, number of pulses, pulse width, period, missing, TV |
| Trigger mode | AUTO, NORMAL, SINGLE, STOP |
| TV trigger (standard)/Line setting range selection/ | NTSC, PAL, Custom/up to 3000/1, 2, 4, 8 |
| Field selection |
| Pulse number trigger setting range | 1 to 9999 events |
| Pulse width trigger time setting range | 15ns~50s |
| Cycle trigger time setting range | 40ns~50s |
| Missing (dropout) | 50ns~50s |
| Trigger time setting range |
| Trigger source | All channels, EXT (±0.5V), EXT10 (±5.0V), line |
| Trigger slope/Coupling | Positive, negative/AC, DC, high frequency removal, low frequency removal, noise removal |
| Display/Resolution |
| Display/Resolution | 7.5-inch color TFT LCD (touch screen)/ VGA:640 x 480 pixels |
| Display format | YT, XY, XY Trigger |
| Vector connection | Sample point interpolation display, dot display |
| Analog persistence | Solid tone display, spectrum display |
| Persistence display time | 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s,infinity |
| Save internal waveform | 5 waveforms |
| (REF memory) |
| AUTO SETUP function | Can be set to Enabled or Disabled |
| Front panel settings save | Five settings can be saved in the internal memory or USB memory device |
| Parameter measurement, cursor, zoom, math, replay |
| Parameter measurement | Maximum value, minimum value, peak value, RMS value, cycle RMS value, average value, cycle average value, top, base, top-base, rising overshoot, falling overshoot, rising time 20-80%, falling time 80-20%, rising time 10-90%, falling time 90-10%, frequency, cycle, number of pulses (positive), number of pulses (negative), |
| pulse width (positive), pulse width (negative), duty ratio, integral, skew (positive/negative), skew @ level |
| Number of simultaneous measurements/statistical value display | Maximum 4 parameters/maximum value, minimum value, number of measurements |
| Cursor | Time, Amplitude, Time & Amplitude, Value at Cursor |
| Zoom | Press the Zoom button on the front panel to display the magnified waveform in a different grid |
| Math function | Addition, subtraction, multiplication, FFT |
| (up to 8k points, rectangular, Hanning, flat top window function) |
| Rescale/unit conversion | a * x + b (x: input voltage, a, b: user-defined)/volt, ampere, watt, °C, no display |
| Replay | Automatic waveform recording, up to 1024 waveforms can be saved and replayed |
| Frequency counter | 6-digit |
| Interface | USB 2.0HS support (device, host), GPIB (factory option DS-576) |
| AUX interface | Connector for external option |
| Waveform data save | Save to USB memory device with binary, ASCII, Mathcad, arithmetic (ASCII), and arithmetic (Mathcad) |
| Hard copy output | Save the image to a USB memory device in TIFF, BMP, or PNG (Transparent) format |
| or output to a PictBridge® -compatible printer |
| Calibration signal output | Square wave 1kHz, 3Vp-p |
| Power supply/power consumption | AC100~240Vrms(50/60Hz), AC100V~120V(400Hz) / 95VA(60W)max |
| Dimensions/Body weight | Approx. 330Wx190Hx124D mm/Approx. 3.7kg |
| Environmental conditions |
| Performance warranty temperature | 10 ~ 35℃ |
| Operating temperature/humidity/altitude | Temperature 0 to 40°C/Humidity 5 to 80% RH ≤ 30°C (no condensation), |
| 55% RH or less 40°C (no condensation)/Altitude 2000m or less |
| Standard Accessories |
| Probes (one for each channel), power cord (1), front panel cover (1), manual (CD-ROM) (1), user’s guide (1) |
| Option |
| GPIB interface | GPIB: IEEE488.2 |
| DS-576 |
| (Factory option) |
| Probe power supply | IWATSU ELECTRIC active probe power supply 2 Series |
| DS-579 |
| (Factory option) |